GAMI

شركة الخليج لصناعة المكيفات ذ.م.م

Gulf Air Conditioning Manufacturing Industries LLC.

AT ESP 25 pa

LOW STATIC  HIGH WATER ΔΤ FAN COILS

 

 

 

 

 

 

 

 

 

MOTOR AT HIGH SPEED

AIR FLOW

AIR FLOW

TOTAL CAPACITY

TOTAL CAPACITY

SENSIBLE CAPACITY

SENSIBLE CAPACITY

SHF

WATER FLOW

WATER PRESSURE DROP

MOTOR

 

DIMENSIONS(mm)

MODEL

m3/h

CFM

KW

BTU/H

KW

BTU/H

 

m3/h

Kpa

watt

RPM

LENGTH

WIDTH

HEIGHT

GFC-09-300-LD-4R

510

300

2.5

8530

2.16

7370

0.86

0.24

51

50

1100

860

550

280

GFC-09-300-LD-6R

510

300

2.9

9895

2.39

8155

0.82

0.28

15

50

1185

860

600

280

GFC-12-400-LD-4R

680

400

3.49

11908

2.93

9997

0.84

0.33

15

80

1220

950

550

280

GFC-12-400-LD-6R

680

400

3.85

13136

3.16

10782

0.82

0.37

27

100

1180

950

600

280

GFC-15-500-LD-4R

850

500

4.32

14740

3.63

12386

0.84

0.41

25

80

1060

1050

550

280

GFC-15-500-LD-6R

850

500

4.87

16616

4.04

13784

0.83

0.46

44

100

1240

1050

600

280

GFC-18-600-LD-4R

1020

600

4.34

14808

4.07

13887

0.94

0.41

27

100

1210

1150

550

280

GFC-18-600-LD-6R

1020

600

5.49

18732

4.64

15832

0.85

0.52

20

150

1220

1150

600

280

GFC-24-800-LD-4R

1360

800

6.83

23304

5.72

19517

0.84

0.65

25

150

1090

1250

550

280

GFC-24-800-LD-6R

1360

800

7.46

25454

6.33

21598

0.85

0.71

42

200

1280

1250

600

280

GFC-30-1000-LD-4R

1700

1000

8.59

29309

7.26

24771

0.85

0.82

41

2X80

1170

1550

550

280

GFC-30-1000-LD-6R

1700

1000

9.32

31800

7.85

26784

0.84

0.89

65

2X120

1300

1550

600

280

GFC-36-1200-LD-4R

2040

1200

8.21

28013

8.01

27330

0.98

0.78

41

2X120

1120

1700

550

280

GFC-36-1200-LD-6R

2040

1200

11.6

39579

9.5

32414

0.82

1.11

33

2X180

1130

1700

600

280

GFC-42-1400-LD-4R

2380

1400

11.8

40262

10.2

34802

0.86

1.13

23

2X150

1105

2050

550

280

GFC-42-1400-LD-6R

2380

1400

13.9

47427

11.3

38556

0.81

1.33

34

2X200

1175

2050

600

280

THE ABOVE DATA ARE BASED ON THE FOLLOWING CONDITIONS

 

 

 

 

 

 

 

 

 

 

AIR FLOW QUANTITY REFERENCED TO STANDARD CONDITIONS (27 C DB/19 C WB)

 

 

 

 

 

 

 

 

WATER FLOW RATE BASED ON HIGH WATER ΔΤ 5.5C IN  14.5 C OUT)

 

 

 

 

 

 

 

 

 

AIR INLET TO THE COIL 27 C DB 19 C WB

 

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE 25 pa

 

 

 

 

 

 

 

 

 

 

 

 

 

[Home] [About] [Products] [Chillers] [Fan Coils] [AHU Modular] [GDA AHU] [Downloads] [HVAC Lab] [Factory] [Contact Us]